{"id":2721,"date":"2026-11-06T16:24:53","date_gmt":"2026-11-06T08:24:53","guid":{"rendered":"https:\/\/haktak.com\/?p=2721"},"modified":"2026-11-06T16:24:56","modified_gmt":"2026-11-06T08:24:56","slug":"choose-tim-liquid-cooled-ai-server-gpu","status":"publish","type":"post","link":"https:\/\/haktak.com\/fr\/choose-tim-liquid-cooled-ai-server-gpu\/","title":{"rendered":"How to Choose a TIM for a Liquid-Cooled AI Server GPU"},"content":{"rendered":"<div class=\"product\"><div class=\"product\">\n<p class=\"wp-block-paragraph\">One GPU in a liquid-cooled rack runs hotter than its neighbors. Le liquide de refroidissement atteint la plaque froide et la pompe semble fonctionner correctement. Quelqu\u2019un sugg\u00e8re d\u2019acheter une p\u00e2te affichant une valeur de W\/(m\u00b7K) plus \u00e9lev\u00e9e. Attendez. Le GPU chaud peut pr\u00e9senter un contact irr\u00e9gulier avec sa plaque, une charge de montage diff\u00e9rente ou un probl\u00e8me plus loin dans le circuit de refroidissement. Changez la p\u00e2te trop t\u00f4t et vous risquez de ne jamais comprendre ce qui n\u2019allait pas.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"900\" height=\"506\" src=\"https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/01_gpu_and_cold_plate.jpg\" alt=\"\u00e0 refroidissement liquide GPU TIM\" class=\"wp-image-2715\" srcset=\"https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/01_gpu_and_cold_plate.jpg 900w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/01_gpu_and_cold_plate-300x169.jpg 300w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/01_gpu_and_cold_plate-768x432.jpg 768w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/01_gpu_and_cold_plate-18x10.jpg 18w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/01_gpu_and_cold_plate-600x337.jpg 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Un mat\u00e9riau d\u2019interface thermique, ou TIM, comble les minuscules espaces entre un bo\u00eetier GPU et la surface qui \u00e9vacue sa chaleur. Le refroidissement liquide d\u00e9place la chaleur <em>apr\u00e8s<\/em> lorsqu\u2019il atteint la plaque froide. Le TIM doit encore lui faire traverser cette premi\u00e8re interface. Pour la conception d\u2019un nouveau serveur d\u2019IA, choisissez le mat\u00e9riau en disposant du bo\u00eetier, de la plaque, de la quincaillerie de montage et du plan de maintenance. Pour un serveur existant pris en charge, suivez le mat\u00e9riau sp\u00e9cifi\u00e9 par le OEM et la proc\u00e9dure de remplacement correspondante.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Commencez par localiser l\u2019interface que vous cherchez \u00e0 r\u00e9parer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Dans un bo\u00eetier \u00e0 couvercle GPU, la chaleur se propage du silicium \u00e0 travers les couches internes du bo\u00eetier jusqu\u2019\u00e0 un couvercle ou \u00e0 un dissipateur thermique int\u00e9gr\u00e9. Un TIM au niveau du syst\u00e8me relie ensuite ce couvercle \u00e0 la plaque froide. Le liquide de refroidissement qui circule dans la plaque \u00e9vacue la chaleur vers le collecteur et l\u2019unit\u00e9 de distribution du liquide de refroidissement, ou CDU. Si la conception expose une puce nue au refroidisseur, ce contact constitue un probl\u00e8me m\u00e9canique et \u00e9lectrique diff\u00e9rent. Ne supposez pas que le m\u00eame pad ou la m\u00eame p\u00e2te conviendra aux deux.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">TIM1 d\u00e9signe g\u00e9n\u00e9ralement l\u2019interface entre la puce et le couvercle \u00e0 l\u2019int\u00e9rieur d\u2019un bo\u00eetier \u00e0 couvercle. TIM2 d\u00e9signe g\u00e9n\u00e9ralement l\u2019interface entre le couvercle et le refroidisseur, install\u00e9e lors de l\u2019assemblage du syst\u00e8me. Certains fournisseurs appellent une jonction entre puce nue et refroidisseur TIM1.5. Ces d\u00e9signations permettent de parler de l\u2019emplacement ; le bo\u00eetier et le sch\u00e9ma de maintenance d\u00e9terminent ce qui peut r\u00e9ellement \u00eatre modifi\u00e9. Un int\u00e9grateur ne peut normalement pas traiter une couche interne au bo\u00eetier comme un \u00e9l\u00e9ment \u00e0 remplacer couramment sur site.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u2019autres composants chauds se trouvent \u00e0 proximit\u00e9. La m\u00e9moire \u00e0 large bande passante (HBM) peut \u00eatre int\u00e9gr\u00e9e au bo\u00eetier de l\u2019acc\u00e9l\u00e9rateur ou se trouver \u00e0 c\u00f4t\u00e9, selon sa construction. Les modules r\u00e9gulateurs de tension (VRM), les \u00e9tages de puissance et les autres composants de la carte peuvent se trouver \u00e0 des hauteurs diff\u00e9rentes. L\u2019espace qui les s\u00e9pare d\u2019un bo\u00eetier ou d\u2019une plaque froide secondaire peut n\u00e9cessiter un pad souple ou un mastic. Ceux de Haktak <a href=\"https:\/\/haktak.com\/fr\/data-centers-ai-servers\/\">Page sur les mat\u00e9riaux thermiques pour serveurs d\u2019IA<\/a> recense ces interfaces voisines avant de choisir une famille de produits.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Emplacement dans le serveur<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>R\u00f4le d\u2019interface probable<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Question \u00e0 trancher en premier<\/strong><\/th><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Bo\u00eetier avec couvercle GPU sur plaque froide<\/td><td class=\"has-text-align-left\" data-align=\"left\">Un joint TIM2 mince et \u00e0 faible r\u00e9sistance<\/td><td class=\"has-text-align-left\" data-align=\"left\">Que sp\u00e9cifie le fabricant du bo\u00eetier ou du serveur concernant la surface, la charge et les conditions de service ?<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Puce nue vers la plaque froide, si utilis\u00e9e<\/td><td class=\"has-text-align-left\" data-align=\"left\">Contact direct, \u00e9troitement contr\u00f4l\u00e9, parfois appel\u00e9 TIM1.5<\/td><td class=\"has-text-align-left\" data-align=\"left\">Qu\u2019est-ce qui prot\u00e8ge la puce et les conducteurs adjacents contre une force excessive ou la pr\u00e9sence de corps \u00e9trangers ?<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">HBM, VRM ou des composants au niveau de la carte vers un refroidisseur<\/td><td class=\"has-text-align-left\" data-align=\"left\">Combler un espace plus important ou irr\u00e9gulier lorsque l\u2019\u00e9quipement en pr\u00e9sente un<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quelle est la plage compl\u00e8te de jeu et la charge admissible des composants ?<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u00c9tanch\u00e9it\u00e9 de la plaque froide et circuit en contact avec le fluide<\/td><td class=\"has-text-align-left\" data-align=\"left\">Maintenir le liquide de refroidissement confin\u00e9 et compatible<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quelles exigences s\u2019appliquent au joint, au fluide et \u00e0 la corrosion ? Un TIM ne peut pas assurer l\u2019\u00e9tanch\u00e9it\u00e9 requise ici.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00e9rifiez le circuit avant de commander des \u00e9chantillons de TIM. Un d\u00e9bit insuffisant du liquide de refroidissement ou un joint d\u00e9fectueux doit \u00eatre trait\u00e9 s\u00e9par\u00e9ment.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Qu\u2019est-ce qui rend d\u00e9licate la liaison entre GPU et la plaque froide ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les surfaces semblent planes jusqu\u2019\u00e0 ce qu\u2019on les mesure. Un grand bo\u00eetier peut pr\u00e9senter une l\u00e9g\u00e8re courbure ; la plaque froide a sa propre tol\u00e9rance de plan\u00e9it\u00e9. Les fixations et les ressorts appliquent la charge en des points pr\u00e9cis. Cela peut laisser un contact ferme pr\u00e8s des vis et une zone moins bien en contact ailleurs. Imaginez que vous pressiez une feuille de papier sur une table l\u00e9g\u00e8rement d\u00e9form\u00e9e : appuyer davantage sur un coin ne permet pas d\u2019aplanir uniform\u00e9ment toutes les parties.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une pression plus \u00e9lev\u00e9e peut am\u00e9liorer le contact et r\u00e9duire l\u2019\u00e9paisseur du TIM. Elle peut \u00e9galement exercer une charge excessive sur une puce, un couvercle ou le substrat d\u2019un bo\u00eetier. Respectez les limites de charge et la s\u00e9quence de serrage d\u00e9finies par le concepteur du mat\u00e9riel, et non une valeur de couple provenant d\u2019un autre serveur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La conductivit\u00e9 thermique du mat\u00e9riau caract\u00e9rise le transfert de chaleur \u00e0 travers celui-ci. La r\u00e9sistance de l\u2019interface apr\u00e8s montage tient compte de l\u2019\u00e9paisseur finale du TIM et du contact sur ses deux faces. Dans le cas simplifi\u00e9 d\u2019une couche uniforme, <code>R = t\/(kA)<\/code>, o\u00f9 <code>t<\/code> est l'\u00e9paisseur, <code>k<\/code> la conductivit\u00e9 et <code>A<\/code> la surface de contact. Dans l\u2019assemblage r\u00e9el s\u2019ajoutent un mouillage imparfait et l\u2019\u00e9talement de la chaleur. Un TIM suppos\u00e9 excellent peut offrir des performances insuffisantes si sa couche est trop \u00e9paisse ou s\u2019il ne couvre pas une partie du couvercle.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Imaginez deux candidats sur le m\u00eame GPU. L\u2019un affiche une conductivit\u00e9 plus \u00e9lev\u00e9e, mais n\u00e9cessite davantage de pression pour \u00e9pouser les surfaces. L\u2019autre mouille la plaque avec la charge disponible et aboutit \u00e0 une ligne de joint plus mince. Lequel fonctionne \u00e0 plus basse temp\u00e9rature ? Il faut r\u00e9aliser le joint pour le d\u00e9terminer. Il s\u2019agit d\u2019une illustration, et non d\u2019un r\u00e9sultat d\u2019essai. Comparez les temp\u00e9ratures ou l\u2019imp\u00e9dance thermique dans des conditions identiques. Le guide de HAKTAK <a href=\"https:\/\/haktak.com\/fr\/thermal-conductivity-vs-thermal-impedance-tim-selection\/\">sur la conductivit\u00e9 thermique et l\u2019imp\u00e9dance<\/a> explique pourquoi ces colonnes des fiches techniques sont faciles \u00e0 confondre.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"900\" height=\"506\" src=\"https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/02_phase_change_sheet_placement.jpg\" alt=\"\u00e0 refroidissement liquide GPU TIM\" class=\"wp-image-2716\" srcset=\"https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/02_phase_change_sheet_placement.jpg 900w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/02_phase_change_sheet_placement-300x169.jpg 300w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/02_phase_change_sheet_placement-768x432.jpg 768w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/02_phase_change_sheet_placement-18x10.jpg 18w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/02_phase_change_sheet_placement-600x337.jpg 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Quelle famille de TIM convient au joint principal GPU ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Commencez par l\u2019exigence OEM ou celle du fabricant du bo\u00eetier. Si vous d\u00e9veloppez un serveur con\u00e7u sur mesure, \u00e9valuez les familles de mat\u00e9riaux au regard du dessin m\u00e9canique et du mod\u00e8le de maintenance. Un mat\u00e9riau de remplissage souple destin\u00e9 \u00e0 combler un interstice au niveau de la carte ne doit pas \u00eatre retenu pour le joint principal GPU simplement parce que sa valeur de conductivit\u00e9 semble impressionnante.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Famille de mat\u00e9riaux<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Quand un essai est justifi\u00e9<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Principal risque lors de la qualification<\/strong><\/th><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">P\u00e2te thermique<\/td><td class=\"has-text-align-left\" data-align=\"left\">Joint mince sous serrage n\u00e9cessitant un bon mouillage de surface<\/td><td class=\"has-text-align-left\" data-align=\"left\">Variation du dosage, effet de pompage, s\u00e9paration de phases, nettoyage et nouvelle application<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Mat\u00e9riau \u00e0 changement de phase (PCM)<\/td><td class=\"has-text-align-left\" data-align=\"left\">Zone contr\u00f4l\u00e9e et processus d\u2019assemblage ; le mat\u00e9riau se ramollit dans sa plage de fonctionnement sp\u00e9cifi\u00e9e<\/td><td class=\"has-text-align-left\" data-align=\"left\">R\u00e8gles d\u2019activation\/rodage, de mise en place, de cyclage et de service \u00e0 usage unique<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">TIM m\u00e9tallique compressible<\/td><td class=\"has-text-align-left\" data-align=\"left\">Conception approuv\u00e9e capable de fournir la pression n\u00e9cessaire et la compatibilit\u00e9 de surface<\/td><td class=\"has-text-align-left\" data-align=\"left\">Conduction \u00e9lectrique, charge de contact, interaction avec les m\u00e9taux et manipulation<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Combleur d\u2019interstice souple, gel ou mastic<\/td><td class=\"has-text-align-left\" data-align=\"left\">Interstices adjacents plus hauts et moins uniformes lorsque le mat\u00e9riel l\u2019exige<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00c9paisseur ou compression excessive au niveau du joint principal mince du GPU<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Graisse : contact mince, application soigneuse<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La graisse peut \u00e9pouser les petites irr\u00e9gularit\u00e9s de surface sans imposer au bo\u00eetier la compression d\u2019une feuille \u00e9paisse. Elle peut donc convenir \u00e0 certaines interfaces entre couvercle et plaque. La quantit\u00e9 appliqu\u00e9e doit \u00eatre reproductible. Un exc\u00e8s peut \u00eatre expuls\u00e9 vers les \u00e9l\u00e9ments voisins ou former une couche \u00e9paisse ; une quantit\u00e9 insuffisante laisse des zones s\u00e8ches. Testez la m\u00e9thode d\u2019impression, de dosage ou d\u2019\u00e9talement pr\u00e9vue sur les pi\u00e8ces r\u00e9elles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une graisse donn\u00e9e peut migrer, se s\u00e9parer ou changer de consistance apr\u00e8s plusieurs cycles. Testez le grade choisi. Haktak <a href=\"https:\/\/haktak.com\/fr\/thermal-grease\/\">cat\u00e9gorie des graisses thermiques<\/a> constitue un point de d\u00e9part pour les interfaces minces et serr\u00e9es, sous r\u00e9serve de l\u2019approbation du fabricant du serveur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">PCM : posez-le \u00e0 froid, puis validez l\u2019interface \u00e0 chaud<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un TIM \u00e0 changement de phase peut \u00eatre fourni sous forme de feuille s\u00e8che pr\u00e9d\u00e9coup\u00e9e ou de couche pr\u00e9appliqu\u00e9e. \u00c0 une temp\u00e9rature sp\u00e9cifi\u00e9e, il ramollit et mouille les surfaces en contact. Cela peut aider une \u00e9quipe de production \u00e0 d\u00e9poser proprement une quantit\u00e9 d\u00e9finie, puis \u00e0 former une interface mince en fonctionnement. Les formulations varient ; le comportement d\u2019activation de la feuille et l\u2019\u00e9paisseur finale de l\u2019interface doivent \u00eatre adapt\u00e9s au bo\u00eetier et \u00e0 la plaque froide utilis\u00e9s.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le premier fonctionnement \u00e0 chaud peut donner des r\u00e9sultats diff\u00e9rents pendant la mise en place du mat\u00e9riau. Suivez la proc\u00e9dure du produit et celle de OEM ; consignez la charge de travail, les conditions du liquide de refroidissement et les temp\u00e9ratures pendant l\u2019essai. Pr\u00e9voyez \u00e9galement le nettoyage et le remplacement. Haktak <a href=\"https:\/\/haktak.com\/fr\/phase-change-thermal-interface-material\/\">cat\u00e9gorie des TIM \u00e0 changement de phase<\/a> pr\u00e9sente ce format, tandis que son <a href=\"https:\/\/haktak.com\/fr\/phase-change-material-vs-thermal-paste\/\">guide comparatif PCM-p\u00e2te<\/a> en expose les compromis.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">TIM m\u00e9tallique : un cas particulier, pas un raccourci<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les interfaces m\u00e9talliques compressibles peuvent offrir une faible r\u00e9sistance thermique dans les conceptions pr\u00e9vues pour les utiliser. Les mat\u00e9riaux \u00e0 base d\u2019indium figurent parmi les options d\u00e9crites pour les bo\u00eetiers de forte puissance. Ils sont \u00e9lectriquement conducteurs, et la charge requise, l\u2019\u00e9tat de surface et la compatibilit\u00e9 doivent \u00eatre rigoureusement ma\u00eetris\u00e9s. Ces contraintes sont encore plus critiques dans un assemblage \u00e0 puce nue. Avant de comparer un TIM m\u00e9tallique \u00e0 un PCM polym\u00e8re ou \u00e0 une graisse thermique, demandez aux concepteurs du bo\u00eetier et du serveur si son utilisation est autoris\u00e9e. Ne placez pas de m\u00e9tal liquide \u00e0 proximit\u00e9 de conducteurs expos\u00e9s dans le cadre d\u2019un essai improvis\u00e9 sur un serveur de production.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Un jeu plus important appelle une autre approche<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A <a href=\"https:\/\/haktak.com\/fr\/thermal-pads\/\">coussinet thermique<\/a> ou <a href=\"https:\/\/haktak.com\/fr\/liquid-gap-filler\/\">mastic thermique liquide<\/a> peut \u00eatre pertinent entre les composants mont\u00e9s sur la carte et un ch\u00e2ssis ou un refroidisseur. Ces composants peuvent pr\u00e9senter diff\u00e9rentes hauteurs et ne tol\u00e9rer qu\u2019un effort limit\u00e9. L\u2019interface GPU entre le capot et la plaque est g\u00e9n\u00e9ralement con\u00e7ue pour \u00eatre beaucoup plus mince. \u00c0 cet endroit, un pad \u00e9pais risque de soulever la plaque, de redistribuer la charge ou d\u2019augmenter la r\u00e9sistance, sauf si le mat\u00e9riel est con\u00e7u en cons\u00e9quence.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cette distinction se retrouve dans des documents de maintenance concrets. Chez Lenovo, la <a href=\"https:\/\/pubs.lenovo.com\/sr780a-v3\/install_front_h100_gpu_cold_plate_module\" rel=\"nofollow noopener\" target=\"_blank\">proc\u00e9dure relative aux plaques froides du SR780a V3 H100\/H200<\/a> prescrit un PCM au niveau des plaques froides GPU et des pads de mastic thermique aux autres emplacements. Elle indique que le PCM et les pads de mastic thermique retir\u00e9s doivent \u00eatre remplac\u00e9s et non r\u00e9utilis\u00e9s, et comprend une proc\u00e9dure de fusion du PCM. Ces instructions s\u2019appliquent \u00e0 cette configuration Lenovo. Elles n\u2019autorisent pas l\u2019emploi d\u2019un mat\u00e9riau de substitution dans la machine d\u2019un autre fabricant. Pour la conception plus g\u00e9n\u00e9rale au niveau de la carte, consultez Haktak : <a href=\"https:\/\/haktak.com\/fr\/thermal-pads-for-ai-servers-high-power-gpus\/\">Guide des pads thermiques pour serveurs d\u2019IA<\/a> est plus pertinent que de supposer qu\u2019un m\u00eame mat\u00e9riau convient \u00e0 tous les composants.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"900\" height=\"506\" src=\"https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/03_direct_to_chip_cooling.jpg\" alt=\"\u00e0 refroidissement liquide GPU TIM\" class=\"wp-image-2717\" srcset=\"https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/03_direct_to_chip_cooling.jpg 900w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/03_direct_to_chip_cooling-300x169.jpg 300w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/03_direct_to_chip_cooling-768x432.jpg 768w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/03_direct_to_chip_cooling-18x10.jpg 18w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/03_direct_to_chip_cooling-600x337.jpg 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Adapter le TIM au mat\u00e9riel de montage et aux conditions limites du fluide de refroidissement<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Avant l\u2019\u00e9chantillonnage, procurez-vous le plan du bo\u00eetier, la surface de contact et la charge admissible. Mesurez la plan\u00e9it\u00e9 de la plaque et du bo\u00eetier, y compris tout cintrage apr\u00e8s assemblage. Indiquez au fournisseur du mat\u00e9riau la plage de tol\u00e9rances que celui-ci doit pouvoir compenser.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ensuite, consignez l\u2019\u00e9tat du fluide de refroidissement \u00e0 l\u2019entr\u00e9e ainsi que la plage de d\u00e9bit. Le TIM transf\u00e8re la chaleur vers la plaque froide, mais celle-ci et la boucle de refroidissement liquide doivent ensuite l\u2019\u00e9vacuer. Si tous les GPUs d\u2019une m\u00eame branche chauffent simultan\u00e9ment \u00e0 mesure que la temp\u00e9rature du fluide de refroidissement augmente, changer d\u2019interface ne r\u00e9soudra pas n\u00e9cessairement le probl\u00e8me \u00e0 l\u2019origine. Si un module pr\u00e9sente un comportement diff\u00e9rent dans des conditions identiques de refroidissement et de charge de travail, v\u00e9rifiez le montage et le contact avant de changer de formulation chimique. Ces tendances orientent l\u2019analyse, mais ne constituent pas \u00e0 elles seules un diagnostic.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Indiquez la charge, la surface, l\u2019\u00e9paisseur finale du joint, la temp\u00e9rature et l\u2019\u00e9tat de surface. Demandez la r\u00e9sistance ou l\u2019imp\u00e9dance thermique dans les conditions pertinentes ; deux valeurs en W\/(m\u00b7K) peuvent avoir \u00e9t\u00e9 obtenues selon des m\u00e9thodes diff\u00e9rentes. M\u00eame une couche mince doit assurer un contact int\u00e9gral, sans vides.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le rack comporte \u00e9galement des interfaces voisines. Les composants d\u2019alimentation et les convertisseurs de stockage d\u2019\u00e9nergie suivent un raisonnement similaire pour le chemin thermique, malgr\u00e9 une g\u00e9om\u00e9trie diff\u00e9rente. Les pages de Haktak consacr\u00e9es aux <a href=\"https:\/\/haktak.com\/fr\/ev-battery-energy-storage\/\">applications pour batteries de v\u00e9hicules \u00e9lectriques et syst\u00e8mes de stockage d\u2019\u00e9nergie<\/a> montrent comment les syst\u00e8mes d\u2019onduleur et de batterie relient une source de chaleur \u00e0 un dispositif de refroidissement. L\u2019espace entre une cellule de batterie et une plaque froide constitue g\u00e9n\u00e9ralement un type d\u2019interface diff\u00e9rent de celui entre un bo\u00eetier GPU et une plaque. Cette page pr\u00e9sente une m\u00e9thode de conception et ne vise pas \u00e0 remplacer le mat\u00e9riau de remplissage d\u2019une batterie par un empilement GPU.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"506\" src=\"https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/04_cold_plate_installation.jpg\" alt=\"\u00e0 refroidissement liquide GPU TIM\" class=\"wp-image-2718\" srcset=\"https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/04_cold_plate_installation.jpg 900w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/04_cold_plate_installation-300x169.jpg 300w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/04_cold_plate_installation-768x432.jpg 768w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/04_cold_plate_installation-18x10.jpg 18w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/04_cold_plate_installation-600x337.jpg 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">La fiabilit\u00e9 et la maintenance d\u00e9terminent si une solution performante en laboratoire r\u00e9sistera \u00e0 l\u2019usage<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le premier essai thermique renseigne peu sur la dur\u00e9e de vie en rack. Apr\u00e8s les cycles et les temps de maintien sp\u00e9cifi\u00e9s, recherchez tout ph\u00e9nom\u00e8ne de pompage, dess\u00e8chement, s\u00e9paration du mat\u00e9riau, croissance des vides ou perte de contact. Le mouillage d\u2019un PCM peut \u00e9voluer lors de la premi\u00e8re exposition \u00e0 la chaleur. Une graisse peut migrer sous l\u2019effet de dilatations r\u00e9p\u00e9t\u00e9es. Une interface m\u00e9tallique soul\u00e8ve des questions de manipulation et de compatibilit\u00e9 des surfaces. Une \u00e9prouvette neuve et impeccable n\u2019est qu\u2019un point de d\u00e9part.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Assemblez plusieurs unit\u00e9s avec des pi\u00e8ces repr\u00e9sentatives de la production. Pour la graisse, consignez la quantit\u00e9, le sch\u00e9ma de d\u00e9pose et le contr\u00f4le effectu\u00e9. Pour le PCM, consignez le retrait du film protecteur, l\u2019orientation, le positionnement et toute op\u00e9ration initiale requise. Pour une plaque au niveau de la carte, mesurez l\u2019\u00e9cartement r\u00e9el et la charge de compression. L\u2019article de Haktak sur la <a href=\"https:\/\/haktak.com\/fr\/thermal-gap-pads-compression-thermal-conductivity\/\">compression des plaques de comblement d\u2019\u00e9cartement<\/a> explique pourquoi les donn\u00e9es de pression doivent accompagner l\u2019indice de conductivit\u00e9 thermique. Soumettez l\u2019ordre de serrage des fixations, les outillages et la propret\u00e9 \u00e0 la gestion des modifications ; une m\u00e9thode d\u2019assemblage diff\u00e9rente peut invalider une comparaison pertinente des mat\u00e9riaux.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La maintenance constitue un autre test. Que se passe-t-il lorsqu\u2019une plaque froide est soulev\u00e9e pour remplacer un module ? L\u2019ancien mat\u00e9riau peut-il \u00eatre \u00e9limin\u00e9 du couvercle sans l\u2019endommager ? Le mat\u00e9riau de remplacement est-il pr\u00e9d\u00e9coup\u00e9, pr\u00e9appliqu\u00e9 ou d\u00e9pos\u00e9 sur place ? Quelles sont les exigences du OEM concernant le mat\u00e9riau neuf, et une proc\u00e9dure contr\u00f4l\u00e9e de premi\u00e8re mise en service est-elle n\u00e9cessaire ? L\u2019exemple de Lenovo ci-dessus r\u00e9pond \u00e0 ces questions pour une configuration de serveur donn\u00e9e. Pour un autre mod\u00e8le, utilisez le manuel correspondant. L\u2019article de Haktak <a href=\"https:\/\/haktak.com\/fr\/test-pcm-thermal-pads-before-production\/\">Guide d\u2019essai PCM<\/a> aide \u00e0 planifier les remontages r\u00e9p\u00e9t\u00e9s et les inspections apr\u00e8s vieillissement, mais ne peut pas se substituer \u00e0 un kit de service OEM.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Conservez les enregistrements des lots et de la manipulation. De la poussi\u00e8re sur une feuille PCM ou sur un pad \u00e9tir\u00e9 peut d\u00e9t\u00e9riorer un mat\u00e9riau pourtant conforme. Inspectez les temp\u00e9ratures au niveau du contact et apr\u00e8s assemblage. Un d\u00e9montage destructif peut r\u00e9v\u00e9ler un angle sec sous une plaque froide par ailleurs soigneusement assembl\u00e9e.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"506\" src=\"https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/05_cold_plate_and_tim_options.jpg\" alt=\"\u00e0 refroidissement liquide GPU TIM\" class=\"wp-image-2719\" srcset=\"https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/05_cold_plate_and_tim_options.jpg 900w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/05_cold_plate_and_tim_options-300x169.jpg 300w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/05_cold_plate_and_tim_options-768x432.jpg 768w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/05_cold_plate_and_tim_options-18x10.jpg 18w, https:\/\/haktak.com\/wp-content\/uploads\/2026\/11\/05_cold_plate_and_tim_options-600x337.jpg 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Normes et \u00e9l\u00e9ments probants : veillez \u00e0 bien distinguer leurs champs d\u2019application<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ASTM D5470 est une m\u00e9thode de d\u00e9termination des propri\u00e9t\u00e9s de transmission thermique de mat\u00e9riaux d\u2019isolation \u00e9lectrique thermiquement conducteurs adapt\u00e9s. Elle peut servir \u00e0 une comparaison contr\u00f4l\u00e9e lorsque l\u2019\u00e9prouvette, la pression, la surface et la temp\u00e9rature sont indiqu\u00e9es. Elle ne permet pas d\u2019homologuer un package GPU, un TIM m\u00e9tallique, une boucle de refroidissement ou un rack finalis\u00e9. Pour les interfaces m\u00e9talliques \u00e9lectriquement conductrices, utilisez la m\u00e9thode valid\u00e9e et l\u2019examen de s\u00e9curit\u00e9 du mat\u00e9riel appropri\u00e9s, plut\u00f4t que de supposer que le m\u00eame cadre applicable \u00e0 l\u2019isolation convient.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le <a href=\"https:\/\/www.opencompute.org\/documents\/ocp-acs-liquid-cooling-cold-plate-requirements-pdf\" rel=\"nofollow noopener\" target=\"_blank\">Document sur les exigences relatives aux plaques froides de l\u2019Open Compute Project<\/a> traite de l\u2019\u00e9cosyst\u00e8me des plaques froides et du refroidissement liquide. Il indique qu\u2019un TIM est couramment utilis\u00e9 entre les composants et les plaques, tout en excluant explicitement le choix du TIM du p\u00e9rim\u00e8tre du document. Reprenez les contraintes m\u00e9caniques et thermiques de la plaque dans la sp\u00e9cification applicable, puis \u00e9tablissez un plan de qualification distinct pour le TIM.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u00e9finissez les essais de cyclage et de vibration, ainsi que les contr\u00f4les d\u2019\u00e9tanch\u00e9it\u00e9 et \u00e9lectriques, \u00e0 partir des exigences du produit, en pr\u00e9cisant les conditions d\u2019exposition et les crit\u00e8res d\u2019acceptation. Une d\u00e9signation \u201c qualit\u00e9 serveur \u201d ou le r\u00e9sultat obtenu sur une \u00e9prouvette ne suffit pas \u00e0 valider un syst\u00e8me install\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Testez d\u2019abord le joint GPU, puis le serveur<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Commencez par \u00e9valuer les \u00e9chantillons dans un montage reproduisant l\u2019interface. Maintenez la pression, la surface, l\u2019\u00e9paisseur et les surfaces de contact constantes lors de la comparaison de la r\u00e9sistance thermique. Si un candidat exige une charge sup\u00e9rieure \u00e0 celle que le bo\u00eetier peut supporter en toute s\u00e9curit\u00e9, \u00e9cartez-le. Une valeur exceptionnelle obtenue sur une \u00e9prouvette \u00e0 une pression inutilisable n\u2019apporte rien.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ensuite, r\u00e9alisez des modules GPU repr\u00e9sentatifs de la production avec la plaque et les \u00e9l\u00e9ments de fixation pr\u00e9vus. Relevez les temp\u00e9ratures avec la m\u00eame charge de travail et dans les m\u00eames conditions de liquide de refroidissement \u00e0 l\u2019entr\u00e9e. V\u00e9rifiez l\u2019uniformit\u00e9 du contact et l\u2019\u00e9paisseur r\u00e9elle du joint de collage sur des assemblages sacrificiels. Mesurez s\u00e9par\u00e9ment le d\u00e9bit et les temp\u00e9ratures du liquide de refroidissement, puis effectuez les contr\u00f4les d\u2019\u00e9tanch\u00e9it\u00e9 requis pour le circuit. Si GPU fonctionne \u00e0 une temp\u00e9rature trop \u00e9lev\u00e9e, le journal doit permettre de d\u00e9terminer si le contact a chang\u00e9 ou si les conditions aux limites du refroidissement ont \u00e9volu\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Soumettez ensuite l\u2019assemblage aux cycles et aux temps de maintien sp\u00e9cifi\u00e9s. R\u00e9p\u00e9tez la charge de travail et l\u2019inspection. Incluez des unit\u00e9s proches des limites admissibles de plan\u00e9it\u00e9 et de montage. Effectuez une reprise sur un jeu selon la proc\u00e9dure approuv\u00e9e. Documentez toute \u00e9tape de manipulation dont d\u00e9pend le r\u00e9sultat.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une grille d\u2019\u00e9valuation facilite l\u2019analyse des compromis :<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Jalon d\u00e9cisionnel<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u00c9l\u00e9ments de preuve \u00e0 conserver<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Raison pour laquelle un candidat peut \u00e9chouer<\/strong><\/th><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Ad\u00e9quation du bo\u00eetier et de OEM<\/td><td class=\"has-text-align-left\" data-align=\"left\">Forme du mat\u00e9riau approuv\u00e9e, plan, limite de charge, r\u00e8gle de service<\/td><td class=\"has-text-align-left\" data-align=\"left\">Le mat\u00e9riau ou le proc\u00e9d\u00e9 est incompatible avec le mat\u00e9riel pris en charge<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Interface de construction neuve<\/td><td class=\"has-text-align-left\" data-align=\"left\">R\u00e9sistance\/temp\u00e9rature \u00e0 la charge sp\u00e9cifi\u00e9e et \u00e0 la limite du liquide de refroidissement<\/td><td class=\"has-text-align-left\" data-align=\"left\">Vides, \u00e9paisseur excessive ou contact irr\u00e9gulier<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Assemblage vieilli<\/td><td class=\"has-text-align-left\" data-align=\"left\">Mesures apr\u00e8s cycle et inspection visuelle\/des contacts<\/td><td class=\"has-text-align-left\" data-align=\"left\">Pump-out, d\u00e9collement ou modification du contact de montage<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Production et retouche<\/td><td class=\"has-text-align-left\" data-align=\"left\">Enregistrements du lot, du dosage\/positionnement, du nettoyage et des reconstructions r\u00e9p\u00e9t\u00e9es<\/td><td class=\"has-text-align-left\" data-align=\"left\">Le r\u00e9sultat de laboratoire ne peut pas \u00eatre reproduit de mani\u00e8re fiable ni faire l\u2019objet d\u2019une maintenance en toute s\u00e9curit\u00e9<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Fournissez au fournisseur un plan de l\u2019interface, et non une conductivit\u00e9 cible<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Transmettez le type de bo\u00eetier, la surface de l\u2019interface, l\u2019\u00e9tat de surface de la plaque froide, la plage de charge et la plage d\u2019\u00e9paisseur de la ligne de collage attendue. Ajoutez les conditions d\u2019entr\u00e9e du liquide de refroidissement et de charge de travail utilis\u00e9es pour la validation. Pr\u00e9cisez s\u2019il s\u2019agit d\u2019un serveur pris en charge par OEM ou d\u2019une nouvelle conception sur mesure. Communiquez les contraintes \u00e9lectriques, les limites de contamination, la fr\u00e9quence des reprises et la m\u00e9thode de production pr\u00e9vue. Demandez les donn\u00e9es thermiques avec la m\u00e9thode d\u2019essai correspondante, les r\u00e9sultats de vieillissement, les instructions de stockage et suffisamment d\u2019\u00e9chantillons pour r\u00e9p\u00e9ter les assemblages.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le prix compte, mais il faut comparer le co\u00fbt de mise en \u0153uvre. Un mat\u00e9riau qui permet d\u2019\u00e9conomiser quelques dollars, mais entra\u00eene une mise en place lente, des rebuts ou un remplacement complexe de la plaque froide, peut s\u2019av\u00e9rer l\u2019option la plus co\u00fbteuse \u00e0 l\u2019\u00e9chelle d\u2019une baie compl\u00e8te. Laissez d\u2019abord les r\u00e9sultats des essais m\u00e9caniques et thermiques r\u00e9duire le choix.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pour un GPU de serveur d\u2019IA \u00e0 refroidissement liquide, le TIM transf\u00e8re la chaleur \u00e0 travers l\u2019interface entre le bo\u00eetier et la plaque, tandis que le mat\u00e9riel maintient l\u2019ensemble en place. Identifiez pr\u00e9cis\u00e9ment cette interface et respectez les r\u00e8gles de OEM. Pour une nouvelle conception, comparez une graisse, un PCM ou une solution m\u00e9tallique approuv\u00e9e \u00e0 l\u2019\u00e9paisseur et \u00e0 la charge r\u00e9elles. V\u00e9rifiez \u00e9galement le c\u00f4t\u00e9 liquide de refroidissement. Le mat\u00e9riau doit fonctionner lors d\u2019assemblages r\u00e9p\u00e9t\u00e9s et apr\u00e8s une intervention de maintenance, pas seulement lors du premier essai sur banc.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Foire aux questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Le refroidissement liquide direct sur puce n\u00e9cessite-t-il toujours un mat\u00e9riau d\u2019interface thermique (TIM)\u00a0?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">G\u00e9n\u00e9ralement, oui. La plaque froide reste en contact avec la surface solide d\u2019un bo\u00eetier ou avec une puce nue, et le mat\u00e9riau d\u2019interface doit combler les petites irr\u00e9gularit\u00e9s. La configuration exacte et le mat\u00e9riau approuv\u00e9 d\u00e9pendent du mat\u00e9riel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">L\u2019interface GPU de la plaque froide est-elle de type TIM1, TIM1.5 ou TIM2\u00a0?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un bo\u00eetier avec couvercle utilise normalement TIM1 \u00e0 l\u2019int\u00e9rieur du bo\u00eetier et TIM2 entre le couvercle et le refroidisseur. Certains fournisseurs utilisent TIM1.5 pour le contact direct entre la puce nue et le refroidisseur. Consultez le plan plut\u00f4t que de supposer que tous les fournisseurs utilisent les m\u00eames d\u00e9signations de mani\u00e8re identique.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Un PCM est-il plus performant qu\u2019une graisse thermique pour un serveur d\u2019IA GPU\u00a0?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Aucun ne s\u2019impose syst\u00e9matiquement. Comparez la r\u00e9sistance thermique apr\u00e8s installation, le positionnement, la pression, les cycles et les conditions d\u2019utilisation dans l\u2019assemblage r\u00e9el. Un PCM peut convenir \u00e0 un positionnement ma\u00eetris\u00e9 ; une graisse peut bien mouiller une interface mince si le proc\u00e9d\u00e9 et la fiabilit\u00e9 sont qualifi\u00e9s.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Un pad thermique souple peut-il remplacer GPU PCM ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Uniquement si le concepteur du serveur ou du bo\u00eetier approuve cette substitution et si l\u2019interface est recon\u00e7ue et test\u00e9e \u00e0 cet effet. Un pad \u00e9pais peut modifier la position de la plaque et la charge appliqu\u00e9e. Pour un serveur pris en charge, il convient d\u2019utiliser le mat\u00e9riau de maintenance sp\u00e9cifi\u00e9.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pourquoi un GPU refroidi par liquide peut-il fonctionner \u00e0 une temp\u00e9rature plus \u00e9lev\u00e9e qu\u2019un autre ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les causes possibles comprennent un contact irr\u00e9gulier du TIM, des diff\u00e9rences de montage, des variations du bo\u00eetier, les conditions du liquide de refroidissement ou la plaque froide elle-m\u00eame. Comparez \u00e0 charge de travail et conditions d\u2019entr\u00e9e identiques, puis inspectez l\u2019interface et la boucle suspectes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Qu\u2019est-ce que le ph\u00e9nom\u00e8ne de pump-out d\u2019un TIM ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il s\u2019agit du d\u00e9placement du mat\u00e9riau d\u2019interface hors de la zone de contact utile sous l\u2019effet de cycles ou de mouvements m\u00e9caniques. Inspectez les assemblages vieillis et mesurez \u00e0 nouveau les performances thermiques dans les m\u00eames conditions que celles utilis\u00e9es pour la mesure de r\u00e9f\u00e9rence.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quelle pression de montage faut-il appliquer au GPU TIM ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Respectez la charge admissible et la proc\u00e9dure d\u2019assemblage d\u00e9finies par les fabricants du bo\u00eetier et de la plaque froide. La pression doit assurer le contact sans endommager la puce, le bo\u00eetier ou la carte. Aucune valeur unique ne convient \u00e0 toutes les GPU conceptions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Puis-je r\u00e9utiliser le PCM apr\u00e8s avoir retir\u00e9 une GPU plaque froide ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Suivez scrupuleusement le manuel du OEM concern\u00e9. La proc\u00e9dure H100\/H200 cit\u00e9e par Lenovo impose d\u2019utiliser un PCM neuf et de nouveaux pads en mastic thermique lorsque la boucle de refroidissement liquide est retir\u00e9e. Cet exemple s\u2019applique uniquement \u00e0 la configuration document\u00e9e.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Les jeux au niveau de la HBM et des VRM doivent-ils \u00eatre combl\u00e9s avec le m\u00eame mat\u00e9riau que celui utilis\u00e9 pour le bo\u00eetier GPU ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pas par d\u00e9faut. Leurs hauteurs, leurs surfaces de contact et leurs limites de charge peuvent \u00eatre diff\u00e9rentes. Certains assemblages utilisent \u00e0 ces emplacements des pads souples ou du mastic thermique, tandis qu\u2019un PCM mince est appliqu\u00e9 \u00e0 l\u2019interface principale du GPU. V\u00e9rifiez chaque emplacement sur le plan du syst\u00e8me.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quelles donn\u00e9es un fournisseur de TIM doit-il fournir ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Demandez les valeurs de r\u00e9sistance ou d\u2019imp\u00e9dance thermique \u00e0 la pression et \u00e0 l\u2019\u00e9paisseur pertinentes, les consignes de manipulation et de stockage du mat\u00e9riau, les r\u00e9sultats des essais de fiabilit\u00e9, les propri\u00e9t\u00e9s \u00e9lectriques si n\u00e9cessaire, ainsi qu\u2019une proc\u00e9dure de reprise clairement d\u00e9finie. Confrontez ces donn\u00e9es aux r\u00e9sultats d\u2019essais r\u00e9p\u00e9t\u00e9s sur votre propre assemblage.<\/p>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>One GPU in a liquid-cooled rack runs hotter than its neighbors. Coolant reaches the cold plate, and the pump seems [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":2720,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[798],"tags":[],"class_list":["post-2721","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tim"],"_links":{"self":[{"href":"https:\/\/haktak.com\/fr\/wp-json\/wp\/v2\/posts\/2721","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/haktak.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/haktak.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/haktak.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/haktak.com\/fr\/wp-json\/wp\/v2\/comments?post=2721"}],"version-history":[{"count":1,"href":"https:\/\/haktak.com\/fr\/wp-json\/wp\/v2\/posts\/2721\/revisions"}],"predecessor-version":[{"id":2722,"href":"https:\/\/haktak.com\/fr\/wp-json\/wp\/v2\/posts\/2721\/revisions\/2722"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/haktak.com\/fr\/wp-json\/wp\/v2\/media\/2720"}],"wp:attachment":[{"href":"https:\/\/haktak.com\/fr\/wp-json\/wp\/v2\/media?parent=2721"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/haktak.com\/fr\/wp-json\/wp\/v2\/categories?post=2721"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/haktak.com\/fr\/wp-json\/wp\/v2\/tags?post=2721"}],"curies":[{"name":"Bien jou\u00e9","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}